XL-3535UV2SB12P1 Dual-Wavelength UV Sterilization LED

XINGLIGHT LED — specifications, applications, sourcing support and RFQ.

XL-3535UV2SB12P1 Dual-Wavelength UV Sterilization LED

RFQ Available Sourcing Support Alternative Matching RoHS
Part Number
XL-3535UV2SB12P1
Manufacturer
XINGLIGHT
Package
3535 SMD, 3.5 x 3.5 x 1.45 mm
Category
LED
Product Type
SMD LED

Quick Sourcing Note

XL-3535UV2SB12P1 from XINGLIGHT is a dual-wavelength UV sterilization LED in a 3535 SMD package measuring 3.5 x 3.5 x 1.45 mm. The device combines a UVC wavelength chip with UVA output, using a purple, plane-lens package. Key operating data includes UVC forward voltage of 5.0 V minimum, 5.5 V typical, and 6.4 V maximum at 40 mA, with UVC peak wavelength from 260 to 280 nm and radiation flux from 3 to 5 mW. UVA operation is specified at 395 nm typical with 40 mW typical radiation flux at 40 mA. The LED is MSL 3 and RoHS compliant.

Specifications

TypeDescription
Part NumberXL-3535UV2SB12P1
ManufacturerXINGLIGHT
Product TypeSMD LED
CategoryLED
Package / Case3535 SMD, 3.5 x 3.5 x 1.45 mm
Outline Dimensions3.5 x 3.5 x 1.45 mm; L/W/H
Luminous Color and LensPurple / plane lens; package description
Moisture Sensitivity LevelMSL 3
Built-in Chip TypeUVC wavelength chip
RoHS ComplianceComplies with RoHS directive
Power Dissipation - UVC200 mW maximum; Ta=25°C
Power Dissipation - UVA200 mW maximum; Ta=25°C
Forward Current - UVC40 mA maximum; Ta=25°C
Forward Current - UVA60 mA maximum; Ta=25°C
Peak Forward Current - UVC100 mA maximum; pulse width <=0.1 ms, duty <=1/10, Ta=25°C
Peak Forward Current - UVA100 mA maximum; pulse width <=0.1 ms, duty <=1/10, Ta=25°C
Operating Temperature-40°C to +60°C; absolute maximum rating, Ta=25°C
Storage Temperature-40°C to +85°C; absolute maximum rating, Ta=25°C
Soldering Temperature260°C maximum, <=6 s; absolute maximum rating
Forward Voltage - UVC5.0 V min, 5.5 V typ, 6.4 V max; IF=40 mA, Ta=25°C
Radiation Flux - UVC3 mW min, 5 mW max; IF=40 mA, Ta=25°C
Peak Wavelength - UVC260 nm min, 270 nm typ, 280 nm max; IF=40 mA, Ta=25°C
Forward Voltage - UVA3.0 V min, 3.4 V max; IF=40 mA, Ta=25°C
Radiation Flux - UVA40 mW typ; IF=40 mA, Ta=25°C
Peak Wavelength - UVA395 nm typ; IF=40 mA, Ta=25°C
Thermal Resistance40°C/W max; Rthj-s, IF=40 mA, Ta=25°C
Junction Temperature125°C; IF=40 mA, Ta=25°C
Radiation Flux Grading P1-23 to 5 mW; IF=40 mA
Radiation Flux Grading P1-830 to 45 mW; IF=40 mA
Radiation Flux Grading P1-945 to 60 mW; IF=40 mA
Voltage Grading N14-55.0 to 5.2 V; IF=40 mA
Voltage Grading N14-65.2 to 5.4 V; IF=40 mA
Voltage Grading N14-75.4 to 5.6 V; IF=40 mA
Voltage Grading N14-85.6 to 5.8 V; IF=40 mA
Voltage Grading N14-95.8 to 6.0 V; IF=40 mA
Voltage Grading N15-16.0 to 6.2 V; IF=40 mA
Voltage Grading N15-26.2 to 6.4 V; IF=40 mA
Voltage Grading N13-43.0 to 3.2 V; IF=40 mA
Voltage Grading N13-53.2 to 3.4 V; IF=40 mA
Wavelength Grading SZ01260 to 270 nm; IF=40 mA
Wavelength Grading SZ02270 to 280 nm; IF=40 mA
Wavelength Grading SZ06395 to 400 nm; IF=40 mA
Wavelength Grading SZ07400 to 405 nm; IF=40 mA
Test Environment Temperature25±5°C unless otherwise indicated
Room Temperature Life Test1000 hours, 22 samples, 0 failures; Ta=25±5°C, IF=40 mA, JIS7021:B4 / JIS7021:B10
High Temperature Storage Test1000 hours, 22 samples, 0 failures; Ta=85±5°C, MIL-STD-202:210A / MIL-STD-750:2031
Low Temperature Storage Test1000 hours, 22 samples, 0 failures; Ta=-35±5°C, JIS7021:B12
High Temperature Humidity Test1000 hours, 22 samples, 0 failures; Ta=85±5°C, RH=85%, JIS7021:B11 / MIL-STD-202:103D
Cold/Heat Strike Test100 cycles, 22 samples, 0 failures; -10±5°C to 100±5°C, 30 min / 5 min / 5 min, JIS7021:B4 / MIL-STD-202:107D / MIL-STD-750:1026
Cold and Heat Cycle Test100 cycles, 22 samples, 0 failures; -35°C to 25°C to 85°C to -35°C, 30 min / 5 min / 30 min / 5 min, JIS7021:A3 / MIL-STD-202:107D / MIL-STD-705:105E
Reliability Judging Criterion - Forward VoltageMaximum initial data x 1.1; VF, IF=40 mA
Reliability Judging Criterion - Reverse Current5 µA maximum; IR, VR=5 V
Reliability Judging Criterion - Luminous IntensityMinimum initial data x 0.7; IV, IF=40 mA
Dimensional Tolerance±0.25 mm unless otherwise noted
Hand Soldering Iron PowerLess than 30 W recommended; manual repair/rework soldering
Hand Soldering TemperatureBelow 300°C; each terminal, one time only
Hand Soldering TimeLess than 3 s per terminal; each terminal, one time only
Reflow Soldering LimitNo more than 2 times; Pb-free reflow soldering
Recommended Maximum Reflow Temperature240±5°C for 6 s; product recommended maximum welding temperature
Cleaning SolventAlcohol recommended after soldering
Cleaning ConditionUnder 30°C for 3 minutes or under 50°C for 30 seconds; alcohol cleaning after soldering
Ultrasonic Cleaning Power300 W maximum recommended; pretest required before cleaning
Unopened Storage Life1 year; moisture-proof anti-electrostatic package with desiccant
Storage Before Opening30°C maximum, 60% RH maximum; before opening package
Storage After Opening30°C maximum, 40% RH maximum; after opening package
Floor Life After Opening168 hours / 7 days; solder within specified storage condition
Recommended Workshop Condition30°C maximum, 60% RH maximum; product operation/workshop environment
Bake Condition60±5°C for 24 hours; if desiccant/package fails or storage time exceeded
Datasheet Statusrequest_only

Product Overview

XL-3535UV2SB12P1 is a XINGLIGHT dual-wavelength UV sterilization LED built in a compact 3535 SMD package. The package outline is 3.5 x 3.5 x 1.45 mm with a purple, plane-lens construction and dimensional tolerance of ±0.25 mm unless otherwise noted.

The device includes a UVC wavelength chip and is specified for both UVC and UVA operation. At IF=40 mA and Ta=25°C, the UVC channel has a forward-voltage range of 5.0 to 6.4 V, 3 to 5 mW radiation flux, and 260 to 280 nm peak wavelength. The UVA channel is specified at 3.0 to 3.4 V, 40 mW typical radiation flux, and 395 nm typical peak wavelength.

Assembly guidance includes MSL 3 handling, reflow soldering no more than two times, a recommended maximum reflow temperature of 240±5°C for 6 seconds, and floor life of 168 hours after opening under specified storage conditions. These parameters support UV sterilization designs requiring paired UVC and UVA emission in a surface-mount LED package.

Key Features

  • 3535 SMD package, 3.5 x 3.5 x 1.45 mm
  • Dual-wavelength UV sterilization LED product type
  • Purple package with plane lens construction
  • Built-in UVC wavelength chip
  • UVC peak wavelength range: 260 to 280 nm
  • UVA peak wavelength: 395 nm typical
  • UVC forward current rated 40 mA maximum
  • UVA forward current rated 60 mA maximum
  • Thermal resistance specified at 40°C/W maximum
  • MSL 3 moisture sensitivity rating
  • RoHS directive compliant process
  • Reflow soldering limited to two times

Typical Applications

  • UV sterilization light modules
  • Dual-wavelength UV emitters
  • UVC and UVA optical assemblies
  • Surface-mount UV LED boards
  • Sterilization equipment light sources
  • UV wavelength grading designs
  • Compact 3535 SMD LED layouts

Procurement Notes

When requesting a quote for XL-3535UV2SB12P1, buyers should confirm the manufacturer, package or case, required quantity, target date code, compliance documents, packing method, destination country and expected delivery schedule.

If alternatives are acceptable, buyers should share the approved vendor list, required electrical or optical limits, package constraints and qualification requirements. Any alternative part should be reviewed by the buyer's engineering team before production use.

For LED and optoelectronic sourcing, brightness bin, wavelength or color temperature bin, forward voltage range, viewing angle, moisture sensitivity level and soldering process limits may affect final selection, availability and lead time.

FAQ

What package does XL-3535UV2SB12P1 use?

XL-3535UV2SB12P1 uses a 3535 SMD package with outline dimensions of 3.5 x 3.5 x 1.45 mm. The datasheet also specifies a purple package with a plane lens and ±0.25 mm dimensional tolerance unless otherwise noted.

What UVC electrical and optical ratings are specified?

For UVC operation at IF=40 mA and Ta=25°C, the forward voltage is 5.0 V minimum, 5.5 V typical, and 6.4 V maximum. Radiation flux is 3 to 5 mW, and peak wavelength is specified from 260 to 280 nm.

What UVA ratings are listed for this LED?

For UVA operation at IF=40 mA and Ta=25°C, the datasheet lists a forward-voltage range of 3.0 to 3.4 V. The UVA radiation flux is 40 mW typical, and the peak wavelength is 395 nm typical.

What handling and storage limits apply after opening?

The LED is MSL 3. After opening, storage is specified at 30°C maximum and 40% RH maximum. Floor life is 168 hours, or 7 days, within the stated storage condition before soldering.

Technical Review & Sourcing Note

Prepared by LDeepAI Component Sourcing Team. Reviewed for RFQ, documentation and alternative sourcing use. Last updated: July 1, 2026.

This page is based on manufacturer datasheet information and LDeepAI sourcing review. Specifications should be verified against the official manufacturer datasheet before final procurement or design approval. Final electrical, optical and reliability approval should be confirmed by the buyer's engineering team.

Request Quote Request Datasheet