Specifications
| Type | Description |
|---|---|
| Part Number | XL-HD2525UGC-A4 |
| Manufacturer | XINGLIGHT |
| Product Type | SMD LED |
| Category | LED |
| Package / Case | 2.5 mm x 2.5 mm x 1.85 mm SMD LED |
| Outline Dimensions | 2.5 x 2.5 x 1.85 mm; L/W/H |
| Luminous Color | Green; transparent colloid |
| Colloid | Transparent; green LED |
| Moisture Sensitivity Level | MSL 3; specified moisture sensitivity level |
| RoHS Compliance | Meets RoHS requirements; environmental protection product |
| Power Dissipation | 3000 mW; Ta=25°C absolute maximum rating |
| Forward Current | 1000 mA; Ta=25°C absolute maximum rating |
| Electrostatic Discharge | 3000 V; Ta=25°C absolute maximum rating |
| Operating Temperature Range | -40 to +105°C; absolute maximum rating |
| Storage Temperature Range | -40 to +85°C; absolute maximum rating |
| Lead Soldering Temperature | 260°C for <=6 s; absolute maximum rating |
| Pulse Width Limit | <=0.1 ms; pulse operation note |
| Duty Cycle Limit | <=1/10; pulse operation note |
| Luminous Flux | 160 min, 225 max lm; IF=700 mA, Ta=25°C |
| Main Wavelength | 515 min, 525 typ, 530 max nm; IF=700 mA, Ta=25°C |
| Peak Wavelength | 525 typ nm; IF=700 mA, Ta=25°C |
| Forward Voltage | 2.6 min, 3.4 max V; IF=700 mA, Ta=25°C |
| Half Light Angle | 120 typ deg; 2θ1/2, IF=700 mA, Ta=25°C |
| Junction Temperature | 125 max °C; Ta=25°C optical-electrical parameter table |
| Reverse Current | 5 max uA; VR=5 V, Ta=25°C |
| Brightness Grade K9 | 160 to 180 lm; IF=700 mA |
| Brightness Grade L1 | 180 to 200 lm; IF=700 mA |
| Brightness Grade L2 | 200 to 225 lm; IF=700 mA |
| Voltage Grade N13-2 | 2.6 to 2.8 V; IF=700 mA |
| Voltage Grade N13-3 | 2.8 to 3.0 V; IF=700 mA |
| Voltage Grade N13-4 | 3.0 to 3.2 V; IF=700 mA |
| Voltage Grade N13-5 | 3.2 to 3.4 V; IF=700 mA |
| Wavelength Grade HG02 | 515 to 520 nm; IF=700 mA |
| Wavelength Grade HG03 | 520 to 525 nm; IF=700 mA |
| Wavelength Grade HG04 | 525 to 530 nm; IF=700 mA |
| Test Environment Temperature | 25 ±5°C; unless otherwise indicated |
| Room Temperature Life Test | 1000 hours, 22 units, 0 failures; Ta=25°C ±5°C, IF=1000 mA; JIS7021:B4/JIS7021:B10 |
| High Temperature Storage Test | 1000 hours, 22 units, 0 failures; Ta=85°C ±5°C; MIL-STD-202:210A/MIL-STD-750:2031 |
| Low Temperature Storage Test | 1000 hours, 22 units, 0 failures; Ta=-35°C ±5°C; JIS7021:B12 |
| High Temperature Humidity Test | 1000 hours, 22 units, 0 failures; Ta=85°C ±5°C, RH=85%; JIS7021:B11/MIL-STD-202:103D |
| Cold/Heat Strike Test | 50 cycles, 22 units, 0 failures; -10°C ±5°C to 100°C ±5°C; 30 min/5 min/5 min; JIS7021:B4/MIL-STD-202:107D/MIL-STD-750:1026 |
| Cold and Heat Cycle Test | 50 cycles, 22 units, 0 failures; -35°C to 25°C to 85°C to -35°C; 5 min/30 min/5 min/30 min/5 min; JIS7021:A3/MIL-STD-202:107D/MIL-STD-705:105E |
| Reliability Judging Criterion Forward Voltage | max initial data x 1.1; IF=1000 mA |
| Reliability Judging Criterion Reverse Current | 10 uA max; VR=5 V |
| Reliability Judging Criterion Luminous Intensity | min initial data x 0.7; IF=1000 mA |
| Dimension Tolerance | ±0.25 mm; unless otherwise noted |
| Hand Soldering Iron Power | <30 W recommended; hand soldering for repair/rework |
| Hand Soldering Temperature | <300°C; soldering iron temperature |
| Hand Soldering Time | <3 s per terminal, one time only; hand soldering |
| Reflow Soldering Limit | not more than 2 times; reflow soldering |
| Recommended Maximum Reflow Temperature | 240 ±5°C for 6 s; product recommended maximum welding temperature |
| Cleaning Solvent | Alcohol recommended; after soldering |
| Cleaning Condition | <=30°C for 3 min or <=50°C for 30 s; alcohol cleaning after soldering |
| Ultrasonic Cleaning Power | <=300 W generally; pretest required to confirm no LED damage |
| Unopened Storage Condition | <=30°C, <60% RH, use within 1 year; before opening package |
| Opened Storage Condition | <=30°C, <40% RH, solder within 168 hours / 7 days; after opening package |
| Recommended Workshop Condition | <=30°C, <60% RH; operation after opening package |
| Baking Condition | 60 ±5°C for 24 hours; if moisture absorbent material has faded or LEDs exceeded storage time |
| Datasheet Status | request_only |
Product Overview
The XL-HD2525UGC-A4 is a XINGLIGHT green high power LED supplied as a 2.5 mm x 2.5 mm x 1.85 mm SMD LED. The luminous color is green, and the package uses transparent colloid. The datasheet identifies the component as an environmental protection product meeting RoHS requirements and specifies MSL 3 moisture sensitivity handling.
Optical and electrical ratings are given at IF=700 mA and Ta=25°C unless noted. Luminous flux is 160 lm minimum to 225 lm maximum, main wavelength is 515 to 530 nm with 525 nm typical peak wavelength, forward voltage is 2.6 to 3.4 V, and the typical half-light angle is 120°. Absolute maximum ratings include 3000 mW power dissipation, 1000 mA forward current, 3000 V ESD rating, and -40 to +105°C operating temperature range.
Assembly guidance includes a 260°C lead soldering limit for no more than 6 seconds, recommended maximum reflow temperature of 240 ±5°C for 6 seconds, and no more than two reflow soldering passes. Storage guidance covers unopened, opened, workshop, cleaning, ultrasonic cleaning, and baking conditions for moisture control.
Key Features
- 2.5 x 2.5 x 1.85 mm SMD package
- Green luminous color with transparent colloid
- 160 to 225 lm at IF=700 mA
- 515 to 530 nm main wavelength range
- 525 nm typical peak wavelength
- 2.6 to 3.4 V forward voltage at 700 mA
- 120° typical half-light angle
- 1000 mA absolute maximum forward current
- 3000 mW absolute maximum power dissipation
- MSL 3 moisture sensitivity level
- RoHS requirements met
- Reflow limited to two soldering passes
Typical Applications
- Green status indication
- Compact SMD lighting modules
- High-current green LED assemblies
- Wide-angle signal lighting
- RoHS-controlled LED designs
- Moisture-sensitive assembly workflows
- Reflow-soldered PCB designs
Procurement Notes
When requesting a quote for XL-HD2525UGC-A4, buyers should confirm the manufacturer, package or case, required quantity, target date code, compliance documents, packing method, destination country and expected delivery schedule.
If alternatives are acceptable, buyers should share the approved vendor list, required electrical or optical limits, package constraints and qualification requirements. Any alternative part should be reviewed by the buyer's engineering team before production use.
For LED and optoelectronic sourcing, brightness bin, wavelength or color temperature bin, forward voltage range, viewing angle, moisture sensitivity level and soldering process limits may affect final selection, availability and lead time.
FAQ
What package is used for XL-HD2525UGC-A4?
XL-HD2525UGC-A4 is specified as a 2.5 mm x 2.5 mm x 1.85 mm SMD LED. The outline dimension tolerance is ±0.25 mm unless otherwise noted in the datasheet.
What optical output is specified at 700 mA?
At IF=700 mA and Ta=25°C, the LED has 160 lm minimum to 225 lm maximum luminous flux. The main wavelength range is 515 to 530 nm, with 525 nm typical peak wavelength.
What are the main electrical limits for this LED?
The datasheet lists 1000 mA forward current, 3000 mW power dissipation, and 3000 V electrostatic discharge as absolute maximum ratings at Ta=25°C. Forward voltage is 2.6 to 3.4 V at IF=700 mA and Ta=25°C.
What soldering limits apply to XL-HD2525UGC-A4?
Lead soldering is limited to 260°C for no more than 6 seconds. Reflow soldering should not exceed two passes, and the recommended maximum reflow temperature is 240 ±5°C for 6 seconds.
How should opened packages be stored before soldering?
After opening the package, the LEDs should be stored at <=30°C and <40% RH and soldered within 168 hours, or 7 days. The recommended workshop condition after opening is <=30°C and <60% RH.
Technical Review & Sourcing Note
Prepared by LDeepAI Component Sourcing Team. Reviewed for RFQ, documentation and alternative sourcing use. Last updated: June 30, 2026.
This page is based on manufacturer datasheet information and LDeepAI sourcing review. Specifications should be verified against the official manufacturer datasheet before final procurement or design approval. Final electrical, optical and reliability approval should be confirmed by the buyer's engineering team.