ADS1292 2-Channel Biopotential Analog Front-End

Texas Instruments Signal_Chain — specifications, applications, sourcing support and RFQ.

ADS1292 2-Channel Biopotential Analog Front-End

RFQ Available Sourcing Support Alternative Matching RoHS
Part Number
ADS1292
Manufacturer
Texas Instruments
Package
32-pin TQFP, 5.00 mm x 5.00 mm; 32-pin VQFN, 4.00 mm x 4.00 mm
Category
Signal Chain
Product Type
Operational Amplifier

Quick Sourcing Note

ADS1292 from Texas Instruments is a Signal_Chain 2-channel biopotential analog front-end supplied in 32-pin TQFP, 5.00 mm x 5.00 mm, and 32-pin VQFN, 4.00 mm x 4.00 mm package options. It integrates simultaneous-sampling 24-bit delta-sigma ADCs, programmable gain settings of 1, 2, 3, 4, 6, 8, or 12, and an SPI-compatible serial interface. Key operating parameters include 125 SPS to 8 kSPS data rates, 335 uW/channel low-power operation, 8 uVPP input-referred noise at 150-Hz bandwidth and G = 6, 120 dB CMRR, and -40°C to +85°C operation. Applications include ECG, patient monitoring, fitness monitors, and multichannel data acquisition.

Specifications

TypeDescription
Part NumberADS1292
ManufacturerTexas Instruments
Product TypeOperational Amplifier
CategorySignal Chain
Package / Case32-pin TQFP, 5.00 mm x 5.00 mm; 32-pin VQFN, 4.00 mm x 4.00 mm
ADC Resolution24-bit
Number of Channels2
ADC ArchitectureDelta-sigma
Programmable Gain1, 2, 3, 4, 6, 8, or 12
Power Consumption Per Channel335 uW/channel
Input-Referred Noise8 uVPP, 150-Hz bandwidth, G = 6
Input Bias Current200 pA
Data Rate125 SPS to 8 kSPS
CMRR120 dB
Analog Supply Voltage2.7 V to 5.25 V
Digital Supply Voltage1.7 V to 3.6 V
Operating Temperature Range-40°C to +85°C
ReferenceBuilt-in reference
OscillatorBuilt-in oscillator
Serial InterfaceSPI-compatible
Right Leg Drive AmplifierBuilt-in
Lead-Off DetectionBuilt-in, using internal excitation current sink or source
Test SignalsBuilt-in
Temperature Monitoring SignalInternally generated
Respiration Impedance MeasurementIntegrated, ADS1292R version only
Input MultiplexerFlexible per-channel input multiplexer
Power ModesFlexible power-down and standby mode
Primary ApplicationsECG, patient monitoring, fitness monitors, multichannel data acquisition
TQFP Package Body Size5.00 mm x 5.00 mm
VQFN Package Body Size4.00 mm x 4.00 mm
Datasheet Statusrequest_only

Product Overview

The ADS1292 is a Texas Instruments 2-channel biopotential analog front-end in the Signal_Chain category. Its signal path is built around simultaneous-sampling 24-bit delta-sigma ADCs with a flexible per-channel input multiplexer. Each channel can be independently connected to internal test signals, a temperature monitoring signal, and lead-off detection signals.

The device supports programmable gain settings of 1, 2, 3, 4, 6, 8, or 12, output data rates from 125 SPS to 8 kSPS, and 120 dB common-mode rejection. Specified parameters include 335 uW/channel power consumption, 8 uVPP input-referred noise over 150-Hz bandwidth at G = 6, and 200 pA input bias current.

Integrated functions include a built-in reference, built-in oscillator, SPI-compatible serial digital interface, built-in right leg drive amplifier, built-in lead-off detection, internally generated test signals, and an internally generated temperature signal. The ADS1292 operates from 2.7 V to 5.25 V analog supplies and 1.7 V to 3.6 V digital supply over -40°C to +85°C. Package options are 32-pin TQFP, 5.00 mm x 5.00 mm, and 32-pin VQFN, 4.00 mm x 4.00 mm.

Key Features

  • Two-channel biopotential analog front-end
  • 24-bit simultaneous-sampling delta-sigma ADCs
  • Programmable gain settings from 1 to 12
  • 125 SPS to 8 kSPS output data rates
  • 335 uW/channel low-power operation
  • 8 uVPP input-referred noise at G = 6
  • 120 dB common-mode rejection ratio
  • Built-in reference and onboard oscillator
  • SPI-compatible serial digital interface
  • Built-in lead-off and right leg drive functions

Typical Applications

  • ECG equipment
  • Patient monitoring systems
  • Fitness monitors
  • Multichannel data acquisition
  • Medical instrumentation signal chains

Procurement Notes

When requesting a quote for ADS1292, buyers should confirm the manufacturer, package or case, required quantity, target date code, compliance documents, packing method, destination country and expected delivery schedule.

If alternatives are acceptable, buyers should share the approved vendor list, required electrical or optical limits, package constraints and qualification requirements. Any alternative part should be reviewed by the buyer's engineering team before production use.

For analog and signal-chain sourcing, supply voltage, bandwidth, accuracy, noise level, package, temperature grade, input/output configuration and qualification requirements should be verified before approval.

FAQ

What type of device is the ADS1292?

The ADS1292 is a Texas Instruments 2-channel biopotential analog front-end in the Signal_Chain category. It includes simultaneous-sampling 24-bit delta-sigma ADCs and is intended for ECG, patient monitoring, fitness monitors, and multichannel data acquisition.

What package options are listed for ADS1292?

The extracted package options are a 32-pin TQFP with a 5.00 mm x 5.00 mm body size and a 32-pin VQFN with a 4.00 mm x 4.00 mm body size.

What data rate and gain ranges does ADS1292 support?

The output data rate range is 125 SPS to 8 kSPS. The programmable gain amplifier supports gain settings of 1, 2, 3, 4, 6, 8, or 12.

Does ADS1292 include internal support functions?

Yes. The extracted facts list a built-in reference, built-in oscillator, SPI-compatible interface, built-in right leg drive amplifier, built-in lead-off detection, internally generated test signals, and an internally generated temperature monitoring signal.

Is respiration impedance measurement included on ADS1292?

Respiration impedance measurement is listed as integrated for the ADS1292R version only. The extracted fact specifically identifies this function with the ADS1292R condition.

Technical Review & Sourcing Note

Prepared by LDeepAI Component Sourcing Team. Reviewed for RFQ, documentation and alternative sourcing use. Last updated: June 30, 2026.

This page is based on manufacturer datasheet information and LDeepAI sourcing review. Specifications should be verified against the official manufacturer datasheet before final procurement or design approval. Final electrical, optical and reliability approval should be confirmed by the buyer's engineering team.

Request Quote Request Datasheet