LTR-C1903 Transient Digitizer Instrument

Texas Instruments Signal_Chain — specifications, applications, sourcing support and RFQ.

LTR-C1903 Transient Digitizer Instrument

RFQ Available Sourcing Support Alternative Matching RoHS
Part Number
LTR-C1903
Manufacturer
Texas Instruments
Package
Category
Signal Chain
Product Type
Operational Amplifier

Quick Sourcing Note

LTR-C1903 is listed as a Texas Instruments Signal_Chain item with extracted documentation describing a transient digitizer instrument. The referenced instrument model is the Tektronix R7912, identified in a service manual first printed in August 1976 under manual part number 070-1590-00. Package case is not specified. Key parameters include analog or digital operating modes, acquired waveform bandwidth up to 500 MHz, 1 GHz direct access bandwidth, digital-mode analog-to-digital conversion, and an effective digital clock rate of about 100 GHz. Documented uses include waveform acquisition, TV-compatible display output, Tektronix interface data transfer, storage monitor operation, and waveform processing package integration.

Specifications

TypeDescription
Part NumberLTR-C1903
ManufacturerTexas Instruments
Product TypeOperational Amplifier
CategorySignal Chain
Package CaseNot specified
Instrument ModelR7912
Instrument TypeTransient Digitizer
Manual ManufacturerTektronix, Inc.
First Printing DateAugust 1976
Manual Part Number070-1590-00
Operating ModesAnalog mode or digital mode
Maximum Acquired Waveform BandwidthUp to 500 MHz
Direct Access Bandwidth1 GHz
Digital Mode FunctionAnalog-to-digital converter
Effective Digital Clock RateAbout 100 GHz
Local Semiconductor MemorySupported with Option 14
Output Display CompatibilityStandard video monitor
Example Compatible Video MonitorsTektronix 630/650-Series
Digital Data TransferTransferred through Tektronix interfaces
Compatible External DevicesComputers, storage display monitors, data logging units
Waveform Processing Package CompatibilityTektronix 2000-Series Waveform Processing Package
Viewing-Only Package ExampleWP2000
Computer-Based Processing Package ExampleWP2321
Interface Standard SupportCAMAC interface standard
Front Panel ControlINTENSITY three-turn control
Focus ControlFOCUS adjustment
Beam Finder FunctionCompresses display into viewing area
Readout ControlREADOUT intensity adjustment
Electronic Graticule ControlGRATICULE intensity adjustment
Calibrator Output High Setting4.0 V peak-to-peak
Calibrator Output Low Setting0.4 V peak-to-peak
Calibrator ConnectorBNC
Calibrator Normal Repetition Rate1 MHz
Calibrator Optional Repetition Rate1 kHz
Probe Power ConnectorFour-pin connector
+GATE OUT ConnectorBNC
Non-Store Mode FunctionConverts acquired signal into TV-compatible format
Storage Monitor ControlSTORE and ERASE controls
Datasheet Statusrequest_only

Product Overview

System-level operation includes conversion of acquired waveforms for viewing on a standard video monitor, including Tektronix 630/650-Series examples. Digital waveform data can transfer through Tektronix interfaces to computers, storage display monitors, and data logging units. The R7912 is also described as compatible with Tektronix 2000-Series Waveform Processing Packages, including WP2000 and WP2321, with some packages supporting CAMAC interface standard integration.

Key Features

  • Analog and digital operating modes
  • Acquired waveform bandwidth up to 500 MHz
  • Direct access operation supports 1 GHz bandwidth
  • Digital mode functions as analog-to-digital converter
  • Effective digital clock rate about 100 GHz
  • Option 14 supports local semiconductor memory
  • Standard video monitor waveform display compatibility
  • Digital data transfer through Tektronix interfaces
  • BNC calibrator connector with selectable output levels
  • STORE and ERASE controls for storage monitor operation

Typical Applications

  • Transient waveform acquisition
  • Digital waveform conversion
  • Standard video monitor display
  • Computer waveform data transfer
  • Storage display monitor integration
  • Data logging unit output
  • Tektronix waveform processing systems
  • CAMAC interface system addition

Procurement Notes

When requesting a quote for LTR-C1903, buyers should confirm the manufacturer, package or case, required quantity, target date code, compliance documents, packing method, destination country and expected delivery schedule.

If alternatives are acceptable, buyers should share the approved vendor list, required electrical or optical limits, package constraints and qualification requirements. Any alternative part should be reviewed by the buyer's engineering team before production use.

For analog and signal-chain sourcing, supply voltage, bandwidth, accuracy, noise level, package, temperature grade, input/output configuration and qualification requirements should be verified before approval.

FAQ

What instrument model is associated with LTR-C1903 facts?

The extracted facts identify the associated instrument model as the Tektronix R7912 Transient Digitizer. The manual source is listed as Tektronix service manual part number 070-1590-00, first printed in August 1976.

What bandwidth parameters are documented for this transient digitizer?

The extracted facts specify acquired waveform bandwidth up to 500 MHz for standard acquired waveforms. Direct access operation is documented with 1 GHz bandwidth, and digital mode has an effective digital clock rate of about 100 GHz.

How can waveform data be displayed or transferred?

Acquired waveforms can be converted for viewing on a standard video monitor, including Tektronix 630/650-Series examples. Digital waveform data can also be transferred through Tektronix interfaces to computers, storage display monitors, and data logging units.

Technical Review & Sourcing Note

Prepared by LDeepAI Component Sourcing Team. Reviewed for RFQ, documentation and alternative sourcing use. Last updated: July 31, 2026.

This page is based on manufacturer datasheet information and LDeepAI sourcing review. Specifications should be verified against the official manufacturer datasheet before final procurement or design approval. Final electrical, optical and reliability approval should be confirmed by the buyer's engineering team.

Request Quote Request Datasheet