HDC2010 Humidity and Temperature Sensor

Texas Instruments Sensor — specifications, applications, sourcing support and RFQ.

HDC2010 Humidity and Temperature Sensor

RFQ Available Sourcing Support Alternative Matching RoHS
Part Number
HDC2010
Manufacturer
Texas Instruments
Package
DSBGA/WLCSP 6-bump, 1.5 mm × 1.5 mm × 0.675 mm nominal
Category
Sensor
Product Type
Humidity and temperature sensor

Quick Sourcing Note

HDC2010 from Texas Instruments is a humidity and temperature sensor in a DSBGA/WLCSP 6-bump package measuring 1.5 mm × 1.5 mm × 0.675 mm nominal. It supports 0% to 100% RH measurement with ±2% RH feature-summary accuracy and temperature accuracy of ±0.2°C typical. The device operates from a 1.62 V to 3.6 V supply and uses an I2C interface with selectable slave addresses set by the ADDR pin. Programmable sampling supports on-demand operation and rates from 5 Hz down to 1/120 Hz. Low-current modes include 50 nA sleep current and 300 nA average current for one RH-only 11-bit measurement per second.

Specifications

TypeDescription
Part NumberHDC2010
ManufacturerTexas Instruments
Product TypeHumidity and temperature sensor
CategorySensor
Package / CaseDSBGA/WLCSP 6-bump, 1.5 mm × 1.5 mm × 0.675 mm nominal
Relative Humidity Measurement Range0% to 100% RH; device capability stated in features
Humidity Accuracy±2% RH; feature summary
Sleep Current50 nA; feature summary
Average Supply Current300 nA; 1 measurement per second, RH only, 11-bit
Average Supply Current550 nA; 1 measurement per second, RH 11-bit + temperature 11-bit
Operating Temperature Range-40°C to 85°C; feature summary operating range
Functional Temperature Range-40°C to 125°C; feature summary functional range
Temperature Accuracy±0.2°C typical; feature summary
Supply Voltage1.62 V to 3.6 V; recommended/operating supply range
Programmable Sampling Rate5 Hz, 2 Hz, 1 Hz, 0.2 Hz, 0.1 Hz, 1/60 Hz, 1/120 Hz, or trigger on demand
InterfaceI2C; digital sensor interface
I2C Slave Address1000000; ADDR pin hardwired to GND
I2C Slave Address1000001; ADDR pin hardwired to VDD
VDD Pin FunctionPositive supply voltage; pin A1
ADDR Pin FunctionAddress select input; pin B1, hardwired to VDD or GND
GND Pin FunctionGround; pin C1
SDA Pin FunctionSerial data line, open-drain, requires pullup resistor to VDD; pin A2, I2C interface
SCL Pin FunctionSerial clock line, open-drain, requires pullup resistor to VDD; pin B2, I2C interface
DRDY/INT Pin FunctionData ready/interrupt, push-pull output; pin C2
Absolute Maximum VDD Pin Voltage-0.3 V to 3.9 V; applied voltage on VDD pin
Absolute Maximum ADDR Pin Voltage-0.3 V to 3.9 V; applied voltage on ADDR pin
Absolute Maximum SCL Pin Voltage-0.3 V to 3.9 V; applied voltage on SCL pin
Absolute Maximum SDA Pin Voltage-0.3 V to 3.9 V; applied voltage on SDA pin
Absolute Maximum DRDY/INT Pin Voltage-0.3 V to VDD + 0.3 V; applied voltage on DRDY/INT pin
Storage Temperature-65°C to 150°C; absolute maximum rating
ESD Rating HBM±2000 V; Human Body Model per ANSI/ESDA/JEDEC JS-001, all pins
ESD Rating CDM±250 V; Charged Device Model per JEDEC JESD22-C101, all pins
Recommended Supply Voltage1.62 V min, 3.6 V max; recommended operating conditions
Temperature Sensor Operating Free-Air Temperature-40°C to 125°C; recommended operating conditions
Relative Humidity Sensor Operating Free-Air Temperature-20°C to 70°C; recommended operating conditions
Integrated Heater Operating Free-Air Temperature-40°C to 85°C; recommended operating conditions
Recommended Relative Humidity Sensor Range20% to 80% RH; non-condensing, recommended over 0°C to 60°C
Junction-to-Ambient Thermal Resistance114.8°C/W; DSBGA YPA, 6 pins
Junction-to-Case Top Thermal Resistance0.8°C/W; DSBGA YPA, 6 pins
Junction-to-Board Thermal Resistance35.2°C/W; DSBGA YPA, 6 pins
Junction-to-Top Characterization Parameter0.6°C/W; DSBGA YPA, 6 pins
Junction-to-Board Characterization Parameter35.4°C/W; DSBGA YPA, 6 pins
RH Measurement Supply Current650 µA typ, 890 µA max; TA=30°C, VDD=1.8 V, 20%≤RH≤80%
Temperature Measurement Supply Current550 µA typ, 730 µA max; TA=30°C, VDD=1.8 V, 20%≤RH≤80%
Sleep Mode Supply Current0.05 µA typ, 0.1 µA max; TA=30°C, VDD=1.8 V, 20%≤RH≤80%
Average Supply Current0.3 µA; 1 measurement/second, RH or temperature only
Average Supply Current0.55 µA; 1 measurement/second, RH 11-bit + temperature 11-bit
Average Supply Current0.3 µA; 1 measurement every 2 seconds, RH 11-bit + temperature 11-bit
Average Supply Current0.105 µA; 1 measurement every 10 seconds, RH 11-bit + temperature 11-bit
Startup Supply Current80 µA; average on startup time
Heater Current90 mA; VDD=3.3 V, heater operating range -40°C to 85°C
RH Accuracy±2% RH typ, ±3% RH max; 20%≤RH≤80%, non-condensing, 0°C≤TA≤60°C; excludes hysteresis and long-term drift
RH Repeatability±0.1% RH; 14-bit resolution
RH Hysteresis±1% RH; TA=30°C, VDD=1.8 V, 20%≤RH≤80%
RH Response Time8 s; t63% step response
RH Conversion Time275 µs; 9-bit accuracy
RH Conversion Time400 µs; 11-bit accuracy
RH Conversion Time660 µs; 14-bit accuracy
RH Long-Term Drift±0.25% RH/year; relative humidity sensor
Temperature Accuracy±0.2°C typ, ±0.7°C max; 5°C<TA<60°C
Temperature Accuracy±0.2°C typ, ±0.4°C max; 15°C<TA<45°C
Temperature Repeatability±0.1°C; 14-bit resolution
Temperature Conversion Time225 µs; 9-bit accuracy
Temperature Conversion Time350 µs; 11-bit accuracy
Temperature Conversion Time610 µs; 14-bit accuracy
Temperature Supply Sensitivity0.05°C/V; VDD from 1.8 V to 3.3 V
Output Data RateOn demand, 5 Hz, 2 Hz, 1 Hz, 0.2 Hz, 0.1 Hz, 1/60 Hz, 1/120 Hz; selectable output data rate
Datasheet Statusrequest_only

Product Overview

The HDC2010 is a Texas Instruments humidity and temperature sensor intended for digital environmental measurement through an I2C interface. It provides relative humidity measurement from 0% to 100% RH and temperature measurement across the specified device temperature ranges. The device supports selectable output data rates, including on-demand conversion, 5 Hz, 2 Hz, 1 Hz, 0.2 Hz, 0.1 Hz, 1/60 Hz, and 1/120 Hz.

The package is a 6-bump DSBGA/WLCSP with nominal dimensions of 1.5 mm × 1.5 mm × 0.675 mm. Pins include VDD, GND, ADDR, SDA, SCL, and DRDY/INT. SDA and SCL are open-drain I2C lines requiring pullup resistors to VDD, while DRDY/INT is a push-pull data-ready or interrupt output.

Key operating values include a 1.62 V to 3.6 V recommended supply range, ±2% RH typical humidity accuracy over the stated RH test range, and ±0.2°C typical temperature accuracy under specified temperature conditions. Current consumption depends on measurement mode, resolution, and rate, with specified sleep, measurement, startup, heater, and average-current values for low-duty-cycle sensor operation.

Key Features

  • 0% to 100% RH measurement capability
  • ±2% RH feature-summary humidity accuracy
  • ±0.2°C typical temperature accuracy
  • 1.62 V to 3.6 V supply range
  • I2C interface with selectable ADDR pin addressing
  • Open-drain SDA and SCL lines require pullups
  • Programmable sampling from 5 Hz to 1/120 Hz
  • 50 nA sleep current stated in feature summary
  • 6-bump DSBGA/WLCSP 1.5 mm square package
  • Push-pull DRDY/INT data-ready interrupt output

Typical Applications

  • Humidity and temperature monitoring
  • I2C environmental sensor modules
  • Low-duty-cycle sensor nodes
  • Battery-supplied measurement systems
  • Data-ready interrupt sensor designs
  • Compact DSBGA sensor assemblies
  • On-demand humidity measurements
  • Temperature-compensated sensing designs

Procurement Notes

When requesting a quote for HDC2010, buyers should confirm the manufacturer, package or case, required quantity, target date code, compliance documents, packing method, destination country and expected delivery schedule.

If alternatives are acceptable, buyers should share the approved vendor list, required electrical or optical limits, package constraints and qualification requirements. Any alternative part should be reviewed by the buyer's engineering team before production use.

For memory and storage sourcing, density, organization, speed grade, voltage, package, temperature grade, date code, lifecycle status and original packing condition should be verified before approval.

FAQ

What type of sensor is the HDC2010?

The HDC2010 is a Texas Instruments humidity and temperature sensor. It measures relative humidity from 0% to 100% RH and provides temperature measurement with ±0.2°C typical accuracy stated in the feature summary.

What supply voltage range does HDC2010 support?

The HDC2010 recommended supply range is 1.62 V minimum to 3.6 V maximum. The datasheet facts also list absolute maximum applied voltage limits for VDD and several interface pins separately.

How does the HDC2010 communicate with a host controller?

The HDC2010 uses an I2C digital sensor interface. SDA and SCL are open-drain lines requiring pullup resistors to VDD, and the ADDR pin selects slave address 1000000 when tied to GND or 1000001 when tied to VDD.

What package is used for the HDC2010 sensor?

The device is supplied in a 6-bump DSBGA/WLCSP package with nominal dimensions of 1.5 mm × 1.5 mm × 0.675 mm. The extracted pin functions include VDD, ADDR, GND, SDA, SCL, and DRDY/INT.

What output data rates are available on HDC2010?

Selectable output data rates include on-demand operation, 5 Hz, 2 Hz, 1 Hz, 0.2 Hz, 0.1 Hz, 1/60 Hz, and 1/120 Hz. The same rates are listed in the programmable sampling and output data rate facts.

Technical Review & Sourcing Note

Prepared by LDeepAI Component Sourcing Team. Reviewed for RFQ, documentation and alternative sourcing use. Last updated: June 30, 2026.

This page is based on manufacturer datasheet information and LDeepAI sourcing review. Specifications should be verified against the official manufacturer datasheet before final procurement or design approval. Final electrical, optical and reliability approval should be confirmed by the buyer's engineering team.