Specifications
| Type | Description |
|---|---|
| Part Number | HDC2080 |
| Manufacturer | Texas Instruments |
| Product Type | Humidity and temperature sensor |
| Category | Sensor |
| Package / Case | WSON (DMB), 6-pin, 3.00 mm × 3.00 mm body |
| Relative Humidity Range | 0% to 100% RH; relative humidity sensor, non-condensing |
| Humidity Accuracy | ±2% RH typ, ±3% RH max; 0°C < TA < 60°C, non-condensing |
| Temperature Accuracy | ±0.2°C typ, ±0.4°C max; factory calibrated |
| Supply Voltage Range | 1.62 V to 3.6 V; recommended operating condition, VDD |
| Sleep Mode Current | 0.05 µA typ, 1 µA max; supply current, sleep mode |
| RH Measurement Supply Current | 650 µA typ, 890 µA max; TA = 30°C, VDD = 1.8 V, 20% ≤ RH ≤ 80% |
| Temperature Measurement Supply Current | 550 µA typ, 730 µA max; TA = 30°C, VDD = 1.8 V, 20% ≤ RH ≤ 80% |
| Average Supply Current | 0.3 µA typ; averaged at 1 sample/s, RH or temperature only |
| Average Supply Current | 0.55 µA typ; averaged at 1 sample/s, RH 11-bit and temperature 11-bit |
| Average Supply Current | 0.3 µA typ; averaged at 1 sample per 2 seconds, RH 11-bit and temperature 11-bit |
| Average Supply Current | 0.105 µA typ; averaged at 1 sample per 10 seconds, RH 11-bit and temperature 11-bit |
| Startup Supply Current | 80 µA typ; average on startup time |
| Integrated Heater Current | 90 mA typ; heater enabled, VDD = 3.3 V |
| RH Repeatability | ±0.1% RH; 14-bit resolution |
| RH Hysteresis | ±1% RH; relative humidity sensor |
| RH Response Time | 8 s; t63% step response |
| RH Conversion Time | 275 µs; 9-bit accuracy |
| Temperature Sensor Operating Free-Air Temperature | -40°C to 125°C; recommended operating condition |
| Relative Humidity Sensor Operating Free-Air Temperature | -20°C to 70°C; recommended operating condition |
| Integrated Heater Operating Free-Air Temperature | -40°C to 85°C; recommended operating condition |
| Functional Temperature Range | -40°C to 125°C; device functional range |
| Operating Temperature Range | -40°C to 85°C; device operating range listed in features |
| VDD Absolute Maximum Voltage | -0.3 V to 3.9 V; applied voltage on VDD pin |
| ADDR Absolute Maximum Voltage | -0.3 V to 3.9 V; applied voltage on ADDR pin |
| SCL Absolute Maximum Voltage | -0.3 V to 3.9 V; applied voltage on SCL pin |
| SDA Absolute Maximum Voltage | -0.3 V to 3.9 V; applied voltage on SDA pin |
| DRDY/INT Absolute Maximum Voltage | -0.3 V to VDD + 0.3 V; applied voltage on DRDY/INT pin |
| Storage Temperature | -65°C to 150°C; absolute maximum rating |
| ESD Rating HBM | ±2000 V; human body model, ANSI/ESDA/JEDEC JS-001 |
| ESD Rating CDM | ±500 V; charged device model, JEDEC JESD22-C101 |
| I2C Interface | Supported; SDA and SCL open-drain lines require pullup resistors to VDD |
| ADDR Pin Address Selection | 1000000 or 1000001; unconnected or GND = 1000000; VDD = 1000001 |
| DRDY/INT Output Type | Push-pull output; data ready/interrupt pin |
| Junction-to-Ambient Thermal Resistance | 56.4°C/W; WSON (DMB), 6 pins |
| Junction-to-Case Top Thermal Resistance | 73.6°C/W; WSON (DMB), 6 pins |
| Junction-to-Board Thermal Resistance | 24.0°C/W; WSON (DMB), 6 pins |
| Junction-to-Top Characterization Parameter | 3.8°C/W; WSON (DMB), 6 pins |
| Junction-to-Board Characterization Parameter | 24.0°C/W; WSON (DMB), 6 pins |
| Junction-to-Case Bottom Thermal Resistance | 13.0°C/W; WSON (DMB), 6 pins |
| Datasheet Status | request_only |
Product Overview
The HDC2080 is a Texas Instruments humidity and temperature sensor for systems requiring relative humidity and temperature measurement in a compact package. It is supplied in a WSON (DMB), 6-pin package with a 3.00 mm × 3.00 mm body, and its relative humidity sensor covers 0% to 100% RH under non-condensing conditions.
Recommended VDD operation is 1.62 V to 3.6 V. The humidity accuracy is ±2% RH typical and ±3% RH maximum over 0°C < TA < 60°C under non-condensing conditions, while factory-calibrated temperature accuracy is ±0.2°C typical and ±0.4°C maximum. The temperature sensor recommended operating free-air range is -40°C to 125°C, while the relative humidity sensor recommended free-air range is -20°C to 70°C.
The interface is I2C, using SDA and SCL open-drain lines that require pullup resistors to VDD. The ADDR pin selects address 1000000 when unconnected or tied to GND, or 1000001 when tied to VDD. A push-pull DRDY/INT pin provides data-ready or interrupt output, and an integrated heater is specified with 90 mA typical current at VDD = 3.3 V.
Key Features
- 0% to 100% RH non-condensing measurement range
- ±2% RH typical humidity accuracy from 0°C to 60°C
- Factory-calibrated ±0.2°C typical temperature accuracy
- 1.62 V to 3.6 V recommended VDD range
- 0.05 µA typical sleep-mode supply current
- I2C interface with open-drain SDA and SCL lines
- ADDR pin selects 1000000 or 1000001 address
- Push-pull DRDY/INT data-ready or interrupt output
- Integrated heater draws 90 mA typical at 3.3 V
- WSON 6-pin 3.00 mm × 3.00 mm package
Typical Applications
- Humidity monitoring systems
- Temperature sensing nodes
- Low-power sensor modules
- I2C environmental sensing designs
- Data-ready interrupt sensing circuits
- Integrated heater humidity designs
- Compact WSON sensor assemblies
Procurement Notes
When requesting a quote for HDC2080, buyers should confirm the manufacturer, package or case, required quantity, target date code, compliance documents, packing method, destination country and expected delivery schedule.
If alternatives are acceptable, buyers should share the approved vendor list, required electrical or optical limits, package constraints and qualification requirements. Any alternative part should be reviewed by the buyer's engineering team before production use.
For memory and storage sourcing, density, organization, speed grade, voltage, package, temperature grade, date code, lifecycle status and original packing condition should be verified before approval.
FAQ
What supply voltage range does the HDC2080 support?
The HDC2080 recommended VDD operating range is 1.62 V to 3.6 V. The absolute maximum rating for voltage applied to the VDD pin is -0.3 V to 3.9 V.
What interface is used by the HDC2080 sensor?
The HDC2080 supports an I2C interface. Its SDA and SCL lines are open-drain and require pullup resistors to VDD. The ADDR pin selects either address 1000000 or 1000001.
What package is specified for the HDC2080?
The HDC2080 is specified in a WSON (DMB), 6-pin package with a 3.00 mm × 3.00 mm body. Thermal data is listed for the WSON (DMB), 6-pin package.
Technical Review & Sourcing Note
Prepared by LDeepAI Component Sourcing Team. Reviewed for RFQ, documentation and alternative sourcing use. Last updated: June 30, 2026.
This page is based on manufacturer datasheet information and LDeepAI sourcing review. Specifications should be verified against the official manufacturer datasheet before final procurement or design approval. Final electrical, optical and reliability approval should be confirmed by the buyer's engineering team.