Specifications
| Type | Description |
|---|---|
| Part Number | XL-504PDC |
| Manufacturer | XINGLIGHT |
| Product Type | SMD LED |
| Category | LED |
| Appearance Dimension | F5 / 5.5 x 5.0 x 8.7 x 28 mm |
| Optical Function | Infrared receiver tube |
| Lens / Colloid Color | Black colloid |
| RoHS Compliance | Complied with RoHS Directive |
| Moisture Sensitivity Level | MSL 2 |
| Standard Packaging | EIA standard packaging |
| Collector-Emitter Voltage | 30 V max; maximum rating |
| Emitter-Collector Voltage | 5 V max; maximum rating |
| Operating Ambient Temperature | -20°C to +85°C; maximum rating |
| Storage Ambient Temperature | -40°C to +85°C; maximum rating |
| Reflow / Wave Soldering Temperature | 240°C max; duration <=6 s; solder point more than 2.0 mm from colloid bottom |
| Manual Welding Temperature | 300°C max; duration 3 s; solder point more than 2.0 mm from colloid bottom |
| Pulse Width Limit | <=0.1 ms; note for maximum ratings |
| Duty Cycle Limit | <=1/10; note for maximum ratings |
| Collector-Emitter Breakdown Voltage | 30 V min; IC=100 uA, Ta=25°C |
| Emitter-Collector Breakdown Voltage | 5 V min; IE=100 uA, Ta=25°C |
| Collector-Emitter Saturation Voltage | 0.8 max; IC=0.1 mA, Ta=25°C; source unit appears as nm and is likely erroneous |
| Collector Dark Current | 100 nA max; VCE=10 V, Ta=25°C |
| Rise Time | 3 us typ; 10%-90%, VCE=5 V, RL=100 ohm, Ta=25°C |
| Fall Time | 3 us typ; 90%-10%, VCE=5 V, RL=100 ohm, Ta=25°C |
| On-State Collector Current Rank 1 | 1 to 2 mA; VCE=5 V, Ee=1 mW/cm², lambda=940 nm, Ta=25°C |
| On-State Collector Current Rank 2 | 2 to 4 mA; VCE=5 V, Ee=1 mW/cm², lambda=940 nm, Ta=25°C |
| On-State Collector Current Rank 3 | 3 to 8 mA; VCE=5 V, Ee=1 mW/cm², lambda=940 nm, Ta=25°C |
| Sensitivity Wavelength | 940 nm; on-state collector current test condition |
| Outline Dimension Unit | Millimeters |
| Outline Dimension Tolerance | ±0.50 mm; unless otherwise mentioned |
| Packaging Type | In bags |
| Packaging Protection | Moisture-proof and anti-electrostatic foil bag |
| Recommended Storage Temperature | <=30°C; storage environment |
| Recommended Storage Relative Humidity | <=70% RH; storage environment |
| Recommended Original Package Storage Time | <=3 months; original box |
| Cleaning Solvent | Ethanol; wipe or soak at room temperature |
| Cleaning Time | <=3 minutes; ethanol at room temperature |
| Lead Bending Distance | >=2 mm from colloid; bracket / lead forming |
| ESD Human Body Model Limit | <1000 V; use anti-static protection |
| ESD Machine Model Limit | <100 V; use anti-static protection |
| Datasheet Status | request_only |
Product Overview
The XL-504PDC is a XINGLIGHT infrared receiver tube categorized as an LED component. Its appearance dimension is specified as F5 / 5.5 x 5.0 x 8.7 x 28 mm, with outline dimensions given in millimeters and a general tolerance of ±0.50 mm unless otherwise mentioned. The lens or colloid color is black colloid.
Electrical maximum ratings include 30 V max collector-emitter voltage and 5 V max emitter-collector voltage. The operating ambient temperature range is -20°C to +85°C, while storage ambient temperature is -40°C to +85°C. For pulse conditions, the datasheet notes a pulse width limit of <=0.1 ms and duty cycle limit of <=1/10.
At Ta=25°C, the datasheet lists 30 V min collector-emitter breakdown voltage at IC=100 uA, 5 V min emitter-collector breakdown voltage at IE=100 uA, and 100 nA max collector dark current at VCE=10 V. Response timing is 3 us typical rise time and 3 us typical fall time under VCE=5 V and RL=100 ohm test conditions. Assembly guidance covers soldering limits, lead bending distance, storage, cleaning, and ESD precautions.
Key Features
- Infrared receiver tube optical function
- F5 5.5 x 5.0 x 8.7 x 28 mm appearance
- Black colloid lens or encapsulation color
- 940 nm sensitivity wavelength test condition
- 30 V max collector-emitter voltage rating
- 5 V max emitter-collector voltage rating
- 100 nA max collector dark current
- 3 us typical rise and fall times
- RoHS Directive compliance stated
- MSL 2 moisture sensitivity level
- Moisture-proof anti-electrostatic foil bag packaging
- Lead bending at least 2 mm from colloid
Typical Applications
- 940 nm infrared sensing
- Infrared beam detection
- Remote-control receiver circuits
- Optical object sensing
- Photo interrupter receiver stages
- Infrared presence detection
Procurement Notes
When requesting a quote for XL-504PDC, buyers should confirm the manufacturer, package or case, required quantity, target date code, compliance documents, packing method, destination country and expected delivery schedule.
If alternatives are acceptable, buyers should share the approved vendor list, required electrical or optical limits, package constraints and qualification requirements. Any alternative part should be reviewed by the buyer's engineering team before production use.
For LED and optoelectronic sourcing, brightness bin, wavelength or color temperature bin, forward voltage range, viewing angle, moisture sensitivity level and soldering process limits may affect final selection, availability and lead time.
Alternatives
EVERLIGHT
PT334-6B
Cross-reference candidate from XINGLIGHT replacement table; validate package, optical/electrical parameters, binning and sourcing requirements before substitution.
EVERLIGHT
L-51ROPT1D1
Cross-reference candidate from XINGLIGHT replacement table; validate package, optical/electrical parameters, binning and sourcing requirements before substitution.
Application Verification Recommended
FAQ
What type of component is XL-504PDC?
XL-504PDC is identified in the manufacturer datasheet as an infrared receiver tube from XINGLIGHT. It is categorized here as an LED component and uses an F5 appearance package.
What package dimensions are specified for XL-504PDC?
The datasheet lists the appearance dimension as F5 / 5.5 x 5.0 x 8.7 x 28 mm. Outline dimensions are specified in millimeters with ±0.50 mm tolerance unless otherwise mentioned.
What wavelength is used for collector current testing?
The on-state collector current rankings are tested at lambda=940 nm, with VCE=5 V, Ee=1 mW/cm², and Ta=25°C. The extracted sensitivity wavelength is therefore 940 nm.
What soldering limits apply to this infrared receiver tube?
Reflow or wave soldering is limited to 240°C max for <=6 seconds, with the solder point more than 2.0 mm from the colloid bottom. Manual welding is limited to 300°C max for 3 seconds under the same distance condition.
How should XL-504PDC be stored before use?
Recommended storage conditions are <=30°C and <=70% relative humidity. The original box storage time is specified as <=3 months, and packaging protection is listed as a moisture-proof and anti-electrostatic foil bag.
Technical Review & Sourcing Note
Prepared by LDeepAI Component Sourcing Team. Reviewed for RFQ, documentation and alternative sourcing use. Last updated: June 30, 2026.
This page is based on manufacturer datasheet information and LDeepAI sourcing review. Specifications should be verified against the official manufacturer datasheet before final procurement or design approval. Final electrical, optical and reliability approval should be confirmed by the buyer's engineering team.